3 PHASE FLAMEPROOF INDUCTION MOTORS
Techtop TCD YBX3 series of Ex d flameproof motors are certified for use in Zone 1 hazardous areas.
Certification
The full motor range of TCD YBX3 series complies to IEC60079-0:2011 Explosive atmospheres - Part 0 General requirements & IEC60079-1:2014-06 Explosive atmospheres – Part 1: Equipment protected by flameproof enclosure “d”.
The TCD YBX3 range is specially designed and certified for use in a Zone 1, Groups IIB or IIC, T4 class temperature, Ex d area. This range is certified to IEC/Ex and Atex.
Efficiency
The TCD YBX3 range in 2, 4 & 6 pole complies with MEPS2 requirements of AS/NZS 1359.5.2004 Table A3 (IE3 High Efficiency). Refer GEMS determination 2018.
Motors are tested in accordance with Test Method A of AS/NZS 1359.102.3 as per IEC60034-2-1.
Specification and Operating Parameters
The main dimensions and rated outputs generally conform to IEC60034 and IEC60072.
Motor performance data is designed and based upon:
Motor Construction
Terminal Box
Electrical Connections and Thermistors
80 ~ 132 6 terminals for Star / Delta starting Optional
160 ~ 355 6 terminals for Star / Delta starting Fitted
Note: If star / delta starting is required for frame 132 and below, no thermistor is fitted.
Conduit Sizes
Motor frame Main conduit (X) Auxiliary conduit (X)
80 ~ 112 1 x M25 1 x M20
132 ~ 180 1 x M40 1 x M20
200 ~ 225 1 x M50 1 x M20
250 ~ 355 1 x M63 1 x M20
Paint
Motors are painted with a high-quality alkyd enamel finish in Carmine Red (RAL 3002), the thickness range is between 80 ~ 100 micron.
Options
Suitable for higher ambient temperatures based on deration of kW output.
Fitting of anti-condensation heaters.
Fitting of extended leads from main terminal box.
Suitable for use with VVVF drive based on fitting of 120˚C thermistors.
Force ventilation by fitment of IEC/Ex approved kit.
Bearings & Grease
All motors up to and including 280 frame are fitted with deep groove ball bearings with 80 to 132 frame being shielded type, 160 and above being open re-greaseable type.
All 4/6/8 pole motors in frames 315 and above are fitted with a roller bearing at the drive end, 2 pole motors are fitted with deep groove ball bearings.
We recommend lithium-based grease, please remove the grease plug located at the bottom of the bearing cap at the drive end and at the bottom of the fan cowl at non-drive end prior to greasing, both grease plugs
must be replaced after greasing.
For New Zealand placed web orders : Free Shipping Nationwide.
Note: Rural addresses we will add a small surcharge.